The Gilbarco SK700 Programming Manual typically covers:

To develop or program a feature on a Gilbarco SK700 dispenser, you must access the programming mode through the manager keypad using specific security codes. Accessing Programming Mode

Most "features" or configuration settings are reached by entering the Manager Functions Initialize : Press the key on the manager keypad. Security Code : Enter the master security code, typically , then press Command Input

: The unit enters function mode (often indicated by a "0" on the display), allowing you to input specific Function Codes Common Programming Features & Function Codes

The following codes are used to configure or "develop" specific dispenser behaviors: Kentronics PPU (Price Per Unit) Settings : Used to set or change fuel prices directly at the pump. Maximum Allocation

: Set limits on the maximum volume or amount a customer can dispense in one transaction. Pulse Channel Configuration Function Code 9 : Set the start position of pulse channels (High or Low). Function Code 10

: Set the pulse format (e.g., Channel B lags Channel A by 90°). Communication Timeout Code 40.22

to adjust the PPU communications timeout (default is 10 seconds, often increased to 30 seconds for specific setups). Country Code

allows you to set the country (e.g., "36" for Australia), which automatically loads regional default configurations. This can typically only be done after a Cold Start Kentronics Advanced Feature Deployment

For more complex feature integration, such as multimedia or payment systems: USB Configuration Gilbarco Sk700 Programming Manual

: On Apollo CPU boards, a special USB stick can be used to "Get Config" (Code 8) or "Send New Software" to the pump while in CRIND (Card Reader in Dispenser) : Advanced features like Gilbarco FlexPay™ Applause™ Media System

require a separate diagnostic startup menu accessed via the FlexPay EPP. Note on Safety

: Any procedure requiring internal electronics access necessitates a total electrical shut-off to the unit to prevent fire or explosion. specific feature

(e.g., price changes, pulse settings, or communication protocols) are you trying to configure or develop for the SK700? Programming SK700/SK700-2 Gilbarco | PDF - Scribd

Programming the Gilbarco SK700 and SK700-II dispensers involves using a manager keypad to enter specific security codes (Level 1: 2222, Level 2: 1503, Level 3: 1309) for configuration, with master code 0128 used for resets. Key commands include setting PPU (Command 1), configuring 2-Wire IDs (Command 40), and setting flow rates (Command 80). For comprehensive procedures, refer to the Scribd programming guide or the Gilbarco installation manual.

Understanding the Gilbarco SK700 Programming Manual The Gilbarco SK700 and its successor, the SK700-II, are among the most reliable and widely used fuel dispensers globally. However, for a station owner or technician, accessing the "brains" of the pump requires a solid understanding of the programming manual and the specific command codes used to configure the unit.

Whether you are performing a new installation or adjusting prices, this guide breaks down the essential elements of the Gilbarco SK700 programming process. 1. Accessing the Programming Mode

To make any changes to the SK700, you must first enter the Service Mode. Unlike consumer electronics, fuel dispensers require a physical or electronic "key" to prevent unauthorized tampering with weights and measures.

The Command Console: Most programming is done via the manager’s keypad or a handheld remote programmer. The Gilbarco SK700 Programming Manual typically covers: To

Security Switch: Inside the pump head, there is typically a "Calibration" or "Program" switch that must be toggled to allow permanent changes to metrology settings. 2. Navigation and Command Structure

The SK700 uses a Command-Sub-code system. You enter a primary code to select a category (like "Price" or "System Configuration") and then a sub-code to drill down to specific settings. Common Function Codes:

Level 1 (Manager Level): General stats, such as totals and basic price changes.

Level 2 (Technician Level): Configuration of hydraulic types, blend ratios, and vapor recovery settings.

Level 3 (Weights & Measures): Calibration of the meters (requires breaking the physical seal). 3. Key Programming Tasks Unit Price Programming

One of the most frequent uses for the manual is changing the price per litre or gallon. Enter the manager code. Navigate to the Price Change command (usually command 1). Select the specific Grade or Hose. Input the new price and press Enter to confirm. Calibration and Metering

If the pump is dispensing slightly more or less than the display shows, you must calibrate the meter. The SK700 manual outlines the "K-Factor," which is the electronic pulse count per unit of fuel. Adjusting this value ensures the pump remains accurate and legal for trade. Error Code Diagnostics

The programming manual is also a diagnostic tool. When the pump displays a "Fail" message, you can use the command console to pull the Error Log. Common codes include: Error 20: Pulser failure.

Error 31: Communication timeout with the Point of Sale (POS) system. Error 50: Internal memory error. 4. Safety and Compliance Warning Maximum Allocation : Set limits on the maximum

Programming a Gilbarco SK700 is not just a technical task; it is a legal one. In most jurisdictions:

Sealing: Any change to the volume measurement must be reported to local Weights and Measures authorities.

Safety: Always ensure the power is off or the pump is in a safe state before opening the cabinet to access the programming switches.

The Gilbarco SK700 Programming Manual is an indispensable tool for maintaining fuel accuracy and operational efficiency. While basic price changes can be done by a manager, complex configuration and calibration should always be handled by a certified technician to ensure compliance with safety and trade regulations.

Gilbarco SK700 dispensers use a command-code system for programming, typically accessed via a manager keypad. Programming requires specific security PINs depending on the level of access needed. General Programming Steps Access Manager Mode : Press the key on the manager keypad. Enter Security PIN Level 1 (Basic/Manager) : Default is Level 2 (Service) : Default is Level 4 (Technician/Engineer) : Default is Enter Command Code

: Input the specific code for the parameter you wish to change (e.g., for unit price). Confirm and Exit to save changes and to return to normal operation. Kentronics Common Command Codes The following codes are frequently used for configuration: Set Price Per Unit (PPU) : Command Code (Level 1). Set Pump Number (ID) : Command Code (Level 2). Operations Mode (Two-Wire/Standalone) : Command Code (Level 1). Special Operations (Soft Cold Start/Reboot) : Command Code (Level 2). Volume Pulse Scale : Command Code (Level 4). Cold Start Procedure

A "Cold Start" is required after major repairs or board replacements to reset parameters to defaults. Kentronics Hardware Prep : Power down the pump. Move the switch to the "CAL" position and move the Cold Start link/jumper to the "Cold Start" position on the CPU board. Initialization : Power up the unit. A flashing

should appear on the display, indicating the system is in cold start mode. Basic Setup , enter the master code , and configure the country code (e.g., Code ) before moving the jumper back to its original position. Kentronics

A crucial reference table for codes like:

According to the Gilbarco SK700 Programming Manual, entering the programming mode does not require a keypad—because the SK700 typically lacks one. Instead, programming is performed via a series of dip switches and push-buttons located inside the dispenser’s electronics enclosure.

The Gilbarco SK700 is a petroleum dispenser controller used to manage fuel dispensing, pricing, and pump functions. This programming manual covers initial setup, network and communication settings, price and product configuration, pump control parameters, security, diagnostics, and maintenance tips for technicians.